If your boiler has a pressure gauge on the front, and most modern combi boilers do, you have probably had to top it up at some point. Once in a while, that is normal. Topping it up every week is not. It is your heating system telling you that water is going somewhere.

What the gauge is telling you

A sealed heating system is filled with water to a set pressure. On many boilers that is roughly 1 to 1.5 bar when the system is cold, but your boiler's manual gives the right figure for yours, and that is the one to go by. The reading rises a little when the heating is running, because warm water expands, and settles again when it cools. That movement is normal.

What is not normal is a steady fall over days or weeks, with nobody having bled a radiator.

The usual causes

  • A leak somewhere in the system. Often small and slow, at a radiator valve, a joint, or pipework under a floor.
  • The pressure relief valve letting water out. This is a safety valve that releases water if pressure gets too high. It usually drains through a small pipe to the outside of the house.
  • The expansion vessel. A part inside or near the boiler that absorbs the expansion of warm water. If it is not doing its job, pressure swings too high when hot, the relief valve opens, and the system loses water.
  • Recent bleeding. If you bled radiators recently, a drop afterwards is expected. Top it up once and see whether it holds.

What you can check yourself

  • Write down the reading with the system cold, at the same time each day, for a week. That one habit tells an engineer more than anything else.
  • Look around the radiators and their valves for drips, damp carpet, staining or rust marks.
  • Find the small pipe that runs from the boiler to the outside wall and check whether it is dripping or the wall below it is wet. If it is, mention it when you call.
  • Look underneath the boiler for any sign of water.

If your manual shows you how to repressurise the system, that is a water-side job most homeowners can do. Do not open the boiler casing, and do not attempt anything inside the boiler. That is work for a Registered Gas Installer (RGII).

When to call

Call us if you are topping up more than once or twice a year, if the pressure climbs very high when the heating is on, if water is coming from the outside pipe, or if you can see a leak. Also call if the boiler keeps locking out on low pressure, rather than resetting it again and again.

Repeatedly topping up a leaking system just keeps feeding the leak, and the leak is usually somewhere you would rather find early.

Book a boiler service or tell us what the gauge is doing. That week of readings will be useful.